<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-26 16-46-37
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 21 kHz 16523 3,9400
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,5 dBr 0,39 dBr 2,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 21 kHz MIN: 13 kHz % above 76 kHz: 3,9400 Acquired: 2024/07/26 16.45.33 Total samples: 16523 Equivalent time: 0:13:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 2,3 dBr MIN: -1,5 dBr AVE: 0,39 dBr % above 12,2 dBr: 0,0 Last value: 1,3 dBr (2024/07/26 16.45.33) 16.32 16.34 16.36 16.38 16.40 16.42 16.44 -2 -1 0 1 2 3 Pm [dBr]